USB To MBUS Master Slave Meter BUS Reading Converter Module DATA Communication Debugging Smart Energy Heat Gas Meter
3.8(12 reviews)Your money is held until you receive your order, plus 7 days to report a problem. Refund if it never arrives or is not as described. Payments go through secure, licensed providers (Paystack, OPay).
14 - 23 days
Ships by express courier. Delivery times are estimates and may vary based on customs clearance.
7-day return window
Item must be unused and in original packaging.
Refund via: Original payment method
Warranty: no manufacturer warranty unless the description says so. Faulty, damaged or not-as-described items are covered by our 7-day buyer protection.
cter Driver link download http://115.28.16.44:81/file/6832.zip introM-Bus(Meter Bus) is bus specifically designed to transmit data to consumption measuring instruments (such as water meters, heat meters and gas meters) and counters to meet the needs of network systems and remote meter reading. M-Bus...
cter
Driver link download
http://115.28.16.44:81/file/6832.zip
intro
M-Bus(Meter Bus) is bus specifically designed to transmit data to consumption measuring instruments (such as water meters, heat meters and gas meters) and counters to meet the needs of network systems and remote meter reading. M-Bus consists of a master station, a number of slave stations and a pair of connecting cables, all the slave stations are connected to the bus in parallel, and the master station controls all the serial communication processes on the bus. The master station periodically reads the data from the slave station and sends the current measured data to the master station when the slave station receives a data sending request.
USB to M-Bus main station by serial communication module. Power module. Modem module. Indicator module and protection module. Power module directly obtains power from the USB port. No additional power input. Self-developed modem module. Strong load capacity. Good receiving performance. High communication rate. Indicator prompt The module indicates the power status of the master station and the data sending and receiving status. Prompt bus short circuit and overload; Protection The protection module protects the computer USB port from being damaged in the event of unexpected situations such as overvoltage, overcurrent, and M-Bus current backflow. At the same time, the main station is protected from damage when the bus is touched short circuit, overload and electrostatic shock. This USB to M-Bus main station consumes less than 25mA.
Peculiarity
Standardized design: in line with European EN1434-3 standard. China CJ/T188-2018 standard
No external power supply: USB port direct power supply. No additional power supply is required
Low power consumption: no-load state. Current consumption ≤25mA
Strong carrying capacity: 20 slave stations can be carried
Good receiving performance: A large number of consecutive 0x00 bytes can be fully received. No data loss
High communication rate: The maximum baud rate is 115200bps
Comprehensive protection: USB port overvoltage. Overcurrent protection. M-Bus short circuit. Overload protection.ESD protection
The instructions are more comprehensive: power light indication. Send light indication. Receive light indication
Connection non-polarity: When the slave station accesses the bus, there is no need to consider the polarity of the two M-Bus lines. Just merge
Apply
The bus topology of M-Bus serial communication mode is very suitable for the requirements of utility meters for safe, reliable and low cost networking. Hundreds of slave devices can be connected at a distance of several kilometers, meeting the needs of networking and remote meter reading. At the same time, it can also meet the special requirements of remote power or battery powered systems. M-Bus has many applications in building and industrial energy consumption data acquisition, and is also used in home electronic systems for alarm systems, intelligent lighting, and thermal energy control.
Panel description
USB interface
Both power port and communication port;
Power supply voltage 5V, current 500mA;
The main station is protected by overvoltage and overcurrent.
M-Bus interface
In the main station, three groups of M-BUS interface M+ connected, M- connected;
M+ is the M-BUS current flow out line, M- is the M-BUS current inflow line;
Idle bus voltage 36V, transmission bus voltage 24V, carrying capacity 50mA;
With short circuit protection, overload protection.
Pilot lamp
Power lamp: indicates the status of USB power supply, when the power supply is normal, the light is on, otherwise the light is off;
Send light: indicates the data sending status. When data is sent, the light is on; otherwise, the light is off.
Receiving indicator: indicates the data receiving status. When receiving data, the indicator is on. Otherwise, the indicator is off.
This module is used for MBUS master and slave module communication debugging, and the module is used as the slave to communicate with the host terminal through the USB terminal. The integrated chip FC722 is used as the slave end, which is different from the TSS721A without self-receiving, and has lower bus leakage current than the discrete device circuit integrated chip.The module MBUS signal is completely isolated from the USB signal, so you don't have to worry about MBUS high level damage to the computer USB interface! The MBUS signal circuit takes power from the MBUS bus and has nothing to do with USB!
Features:
1, fully in line withM-BUSInternational standards and national standards
2,Bus current200uA-3mAcontinuous
3, bus voltage12V-42V
4,Enhanced5V, 3.3VRegulated output
5, 300-9600BPSCommunication rate
6,stand byUART,High stability
Application areas:
Communication debugging of master-slave module for simulating
intelligent water meter gas meter heat meter reading meter application
Analog smart grid automatic meter readingApplication master-slave module communication debugging
Analog smart home control networkApplication master-slave module communication debugging
Simulated fire alarm and linkage networkApplication master-slave module communication debugging
Analog central air conditioning control systemApplication master-slave module communication debugging
Analog smart sensor networkApplication master-slave module communication debugging
sample graph:
Master-slave docking test

Tax excluded, add at checkout if applicable
Color:
Quantity
Service commitment
Shipping: ₦2,746.2
14 - 23 days
Return & Refund
7-day return window
Secure Payment
Buyer protection guaranteed
cter
Driver link download
http://115.28.16.44:81/file/6832.zip
intro
M-Bus(Meter Bus) is bus specifically designed to transmit data to consumption measuring instruments (such as water meters, heat meters and gas meters) and counters to meet the needs of network systems and remote meter reading. M-Bus consists of a master station, a number of slave stations and a pair of connecting cables, all the slave stations are connected to the bus in parallel, and the master station controls all the serial communication processes on the bus. The master station periodically reads the data from the slave station and sends the current measured data to the master station when the slave station receives a data sending request.
USB to M-Bus main station by serial communication module. Power module. Modem module. Indicator module and protection module. Power module directly obtains power from the USB port. No additional power input. Self-developed modem module. Strong load capacity. Good receiving performance. High communication rate. Indicator prompt The module indicates the power status of the master station and the data sending and receiving status. Prompt bus short circuit and overload; Protection The protection module protects the computer USB port from being damaged in the event of unexpected situations such as overvoltage, overcurrent, and M-Bus current backflow. At the same time, the main station is protected from damage when the bus is touched short circuit, overload and electrostatic shock. This USB to M-Bus main station consumes less than 25mA.
Peculiarity
Standardized design: in line with European EN1434-3 standard. China CJ/T188-2018 standard
No external power supply: USB port direct power supply. No additional power supply is required
Low power consumption: no-load state. Current consumption ≤25mA
Strong carrying capacity: 20 slave stations can be carried
Good receiving performance: A large number of consecutive 0x00 bytes can be fully received. No data loss
High communication rate: The maximum baud rate is 115200bps
Comprehensive protection: USB port overvoltage. Overcurrent protection. M-Bus short circuit. Overload protection.ESD protection
The instructions are more comprehensive: power light indication. Send light indication. Receive light indication
Connection non-polarity: When the slave station accesses the bus, there is no need to consider the polarity of the two M-Bus lines. Just merge
Apply
The bus topology of M-Bus serial communication mode is very suitable for the requirements of utility meters for safe, reliable and low cost networking. Hundreds of slave devices can be connected at a distance of several kilometers, meeting the needs of networking and remote meter reading. At the same time, it can also meet the special requirements of remote power or battery powered systems. M-Bus has many applications in building and industrial energy consumption data acquisition, and is also used in home electronic systems for alarm systems, intelligent lighting, and thermal energy control.
Panel description
USB interface
Both power port and communication port;
Power supply voltage 5V, current 500mA;
The main station is protected by overvoltage and overcurrent.
M-Bus interface
In the main station, three groups of M-BUS interface M+ connected, M- connected;
M+ is the M-BUS current flow out line, M- is the M-BUS current inflow line;
Idle bus voltage 36V, transmission bus voltage 24V, carrying capacity 50mA;
With short circuit protection, overload protection.
Pilot lamp
Power lamp: indicates the status of USB power supply, when the power supply is normal, the light is on, otherwise the light is off;
Send light: indicates the data sending status. When data is sent, the light is on; otherwise, the light is off.
Receiving indicator: indicates the data receiving status. When receiving data, the indicator is on. Otherwise, the indicator is off.
This module is used for MBUS master and slave module communication debugging, and the module is used as the slave to communicate with the host terminal through the USB terminal. The integrated chip FC722 is used as the slave end, which is different from the TSS721A without self-receiving, and has lower bus leakage current than the discrete device circuit integrated chip.The module MBUS signal is completely isolated from the USB signal, so you don't have to worry about MBUS high level damage to the computer USB interface! The MBUS signal circuit takes power from the MBUS bus and has nothing to do with USB!
Features:
1, fully in line withM-BUSInternational standards and national standards
2,Bus current200uA-3mAcontinuous
3, bus voltage12V-42V
4,Enhanced5V, 3.3VRegulated output
5, 300-9600BPSCommunication rate
6,stand byUART,High stability
Application areas:
Communication debugging of master-slave module for simulating
intelligent water meter gas meter heat meter reading meter application
Analog smart grid automatic meter readingApplication master-slave module communication debugging
Analog smart home control networkApplication master-slave module communication debugging
Simulated fire alarm and linkage networkApplication master-slave module communication debugging
Analog central air conditioning control systemApplication master-slave module communication debugging
Analog smart sensor networkApplication master-slave module communication debugging
sample graph:
Master-slave docking test
No questions yet. Ask about size, compatibility, delivery or anything else.
Sign in to ask a question.
| Category | Measurement & Layout Tools |
|---|---|
| Color options | USB to MBUS Slave, USB to MBUS Master |
| Brand Name | NONE |
| Origin | Mainland China |
| High-concerned chemical | None |
| Semi-finishedproduct | Yes |
| DIY Supplies | Electrical |
| Electronic | No |
| Type | USB to MBUS Master Converter |
| Output Voltage | 5v |
| Data Record | No |
| Style | M-BUS meter |
| Certification | NONE |
| Model Number | USB TO MBUS Slave Converter |
| USB to MBUS Master | USB MBUS Slave |
| Choice | yes |
| Semi_Choice | yes |