Smart Wifi Thermostat Humdistat AC 110V 220V Digital Temperature Humidity Controller Incubator Heating Cooling Thermoregulator
Your money is held until you receive your order, plus 7 days to report a problem. Refund if it never arrives or is not as described. Payments go through secure, licensed providers (Paystack, OPay).
16 - 30 days
Ships by express courier. Delivery times are estimates and may vary based on customs clearance.
7-day return window
Item must be unused and in original packaging.
Refund via: Original payment method
Warranty: no manufacturer warranty unless the description says so. Faulty, damaged or not-as-described items are covered by our 7-day buyer protection.
AC 110V 220V Digital Temperature Controller DTC1200 Thermostat Thermoregulator Sensor Meter For Incubator Cooling Heating FridgePackage Include: Type 11 x DTC1200 Intellligent Temperature Controller1 x NTC 10K B3950 Temperature sensorType 21 x DTC1100 Intellligent Temperature Controller1 x NTC 10K B...
AC 110V 220V Digital Temperature Controller DTC1200 Thermostat Thermoregulator Sensor Meter For Incubator Cooling Heating Fridge
Package Include:
Type 1
1 x DTC1200 Intellligent Temperature Controller
1 x NTC 10K B3950 Temperature sensor
Type 2
1 x DTC1100 Intellligent Temperature Controller
1 x NTC 10K B3950 Temperature sensor
Type 3
1 x DTC2200 Intellligent Temperature Controller
1 x DS18B20 Temperature sensor
Type 4
1 x DTC1110 Intellligent Temperature Controller
1 x NTC 10K B3950 Temperature sensor
Type 5
1 x DTC2210 Intellligent Temperature Controller
1 x DS18B20 Temperature sensor
Type 6
1 x DTC3200 Intellligent Temperature Humidity Controller
1 x SHT20 Temperature sensor
Type 7
1 x DTC1201 WIFI Intellligent Temperature Controller
1 x NTC 10K B3950 Temperature sensor
1 x WIFI Antenna
1 x User Manual
Type 8
1 x DTC2201 WIFI Intellligent Temperature Controller
1 x DS18B20 Temperature sensor
1 x WIFI Antenna
1 x User Manual
DTC1200
Description:
Product Name: Thermostat
Product model: DTC1200
Supply voltage: AC110~230V
Temperature range: -40°C~+99°C
Temperature measurement accuracy: ±1 °C (-40 °C ~ +70 °C)
Sensor line length: 100cm
Thermostat size: 93mm*56mm*34mm
Output capacity: cooling (compressor 3A) heating (10A/250VAC)
View parameter methods:
When the thermostat is working normally, press and release the key once to display the temperature setting value; press and release the key once to display the temperature difference setting value. After 3 seconds, the temperature returns to the normal display state.
Set the parameter method:
When the thermostat is working normally, press and hold the S button for more than 3 seconds to enter the modified parameter mode. The "Set" indicator lights up, the digital tube displays the code "F1" of the first menu item, and press the up or down button to increase or decrease the value. The code of the menu item, press S key to display the parameter setting value of the current menu, press and hold the S key, then press the up or down key to increase or decrease the parameter setting value of the current menu; press and hold the S key Do not hold, while long press the up or down button to quickly up or down and display the parameter settings of the current menu.
Press and hold the up and down keys at the same time to restore the parameters to the factory settings.
Operating instructions:
When the thermostat is working normally, press and hold the power button for more than 3 seconds to turn off the thermostat. When the thermostat is off, press and hold the power button for more than 3 seconds to open the thermostat.
When the thermostat is working normally, the digital tube displays the current temperature measurement value, and performs automatic recognition conversion of the cooling heating operation mode.
When the measured temperature ≥ temperature set value + temperature difference set value, enter the cooling state, the Cool indicator light is on, the cooling relay normally open contact is closed; the Cool indicator flashes, indicating that the cooling device is in the press delay protection state; when measuring the temperature ≤ temperature set value, the Cool indicator is off, and the normally open contact of the refrigeration relay is disconnected.
When the measured temperature ≤ temperature set value - temperature difference set value enters the heating state, the Heat indicator light is on, the heating relay normally open contact is closed; when the measured temperature ≥ temperature set value, the Heat indicator is off, the heating relay normally open contact disconnect.
Repair system data:
After the thermostat is powered on, first check whether the parameter settings are correct. If an error is detected, "Er" is displayed. Pressing any key will restore the default parameter settings and work normally. It is recommended to reset the parameters at this time.
System code, reason and action:
Sensor fault alarm: When the temperature probe loop is short-circuited or open-circuit fault, the thermostat starts the probe fault alarm mode, closes all execution states, and the digital tube displays "EE". After the fault is cleared, press any key to return to the normal working mode.
Over-temperature alarm: When the temperature measurement exceeds the temperature measurement range, the thermostat starts the over-temperature limit fault alarm mode, and all execution states are turned off. The digital tube displays "HH". When the temperature returns to the normal measurement range, press any key. Return to normal working mode.
DTC1100
Description:
Power supply voltage: AC110 ~ 220V
Temperature range: -40 ℃ ~ + 99 ℃
Temperature measurement accuracy: ± 1 ℃ (-40 ℃ ~ + 70 ℃)
Sensor line length: 100cm
Thermostat size: 93mm * 56mm * 34mm
Output capacity: cooling (10A / 250VAC) heating (10A / 250VAC)
Parameter setting method:
When the thermostat works normally, short press the button, the set temperature value flashes, modify the set temperature parameter by either long press or short press; press and hold the key for more than 3 seconds to enter the parameter modification mode, the digital tube displays the first menu item Code "HC", press or key to increase or decrease the code of the menu item, press the key to display the parameter setting value of the current menu, short press or key to increase or decrease and display the parameter setting value of the current menu.
Press and hold the button to restore the parameters to the factory settings.
Operating instructions:
When the thermostat is working normally, press and hold the power button for more than 3 seconds to turn off the thermostat. When the thermostat is off, short press the power button to turn on the thermostat.
When the thermostat works normally, the digital tube displays the current temperature measurement value.
First set the temperature control working state, heating or cooling.
Heating mode: When the measured temperature ≤ temperature set value-temperature difference set value, the Work indicator lights, the relay normally open contact closes; the Work indicator flashes, indicating that the press is in the delayed protection state; when the measured temperature ≥ temperature setting Value, the Work indicator is off, and the normally open contact of the relay is disconnected.
Refrigeration mode: When the measured temperature ≥ temperature set value + temperature difference set value, the Work indicator lights, the relay normally open contact is closed; the Work indicator flashes, indicating that the press is in the delayed protection state; when the measured temperature ≤ temperature setting Value, the Work indicator is off, and the normally open contact of the relay is disconnected.
System code, reason and action:
Sensor failure alarm: When the temperature probe circuit has a short circuit or open circuit failure, the thermostat activates the probe failure alarm mode and closes all execution states. The digital tube displays "LLL". After the failure is removed, press any key to return to normal working mode.
Over temperature limit alarm: When the temperature measurement exceeds the temperature measurement range, the thermostat starts the over temperature limit fault alarm mode, closes all execution states, the digital tube displays "HHH", when the temperature returns to the normal measurement range, press any key, Return to normal working mode.
DTC2200
Description:
Power supply voltage: AC110 ~ 230V
Temperature range: -40 ℃ ~ + 99 ℃
Temperature measurement accuracy: ± 1 ℃ (-40 ℃ ~ + 70 ℃)
Sensor line length: 100cm
Thermostat size: 93mm * 56mm * 34mm
Output capacity: cooling (10A / 250VAC) heating (10A / 250VAC)
Parameter setting method:
When the thermostat is working normally, press and hold the key for more than 3 seconds to enter the parameter modification mode, the digital tube displays the code of the first menu item "F1", press or to increase or decrease the code of the menu item, press and hold the key , Short press or key to increase or decrease and display the parameter setting value of the current menu; hold down the key, while long press or key to quickly increase or decrease and display the parameter setting value of the current menu.
At the same time, long-press the and keys to restore the parameters to the factory settings.
Operating instructions:
When the thermostat works normally, press and hold the power button for more than 3 seconds to turn off the thermostat. When the thermostat is off, press and hold the power button for more than 3 seconds to turn on the thermostat.
When the thermostat is working normally, the digital tube displays the current temperature measurement value, and performs automatic recognition and conversion of the cooling and heating working mode.
When the measured temperature ≥ temperature set value + temperature difference set value, enter the cooling state, the Cool indicator lights, the refrigeration relay normally open contact is closed; The Cool indicator flashes, indicating that the refrigeration equipment is in the state of delay protection of the press; when the temperature is measured ≤The temperature setting value, the Cool indicator is off, and the normally open contact of the cooling relay is disconnected.
When the measured temperature ≤ temperature set value-temperature difference set value enters the heating state, the Heat indicator lights, the heating relay normally open contact is closed; when the measured temperature ≥ temperature set value, the Heat indicator turns off, the heating relay normally open contact disconnect.
Cool indicator: On: cooling operation; off: cooling off; flashing: press delay
Heat indicator: On: heating work; off: heating off
Set indicator on: parameter setting status
note:Cool and Heat LEDs cannot be on at the same time
Repair system data:
After the thermostat is powered on, first check whether the parameter settings are correct. If an error is detected, "Er" is displayed. At this time, press any key to restore the default parameter settings and work normally. It is recommended to reset the parameters at this time.
System code, reason and action:
Sensor failure alarm: When the temperature probe circuit has a short circuit or open circuit failure, the thermostat activates the probe failure alarm mode and closes all execution states. The digital tube displays "EE". After the failure is removed, press any key to return to the normal working mode.
Over temperature limit alarm: When the temperature measurement exceeds the temperature measurement range, the thermostat activates the over temperature limit fault alarm mode, closes all execution states, the digital tube displays "HH", when the temperature returns to the normal measurement range, press any key, Return to normal working mode.
DTC1110
Description:
Power supply voltage: AC110 ~ 220V
Temperature range: -40 ℃ ~ + 99 ℃
Temperature measurement accuracy: ± 1 ℃ (-40 ℃ ~ + 70 ℃)
Sensor line length: 100cm
Thermostat size: 93mm * 56mm * 34mm
Output capacity: cooling (10A / 250VAC) heating (10A / 250VAC)
Parameter setting method:
When the thermostat works normally, short press the button, the set temperature value flashes, modify the set temperature parameter by either long press or short press; press and hold the key for more than 3 seconds to enter the parameter modification mode, the digital tube displays the first menu item Code "HC", press or key to increase or decrease the code of the menu item, press the key to display the parameter setting value of the current menu, short press or key to increase or decrease and display the parameter setting value of the current menu.
Press and hold the button to restore the parameters to the factory settings.
Operating instructions:
When the thermostat is working normally, press and hold the power button for more than 3 seconds to turn off the thermostat. When the thermostat is off, short press the power button to turn on the thermostat.
When the thermostat works normally, the digital tube displays the current temperature measurement value.
First set the temperature control working state, heating or cooling.
Heating mode: When the measured temperature ≤ temperature set value-temperature difference set value, the Work indicator lights, the relay normally open contact closes; the Work indicator flashes, indicating that the press is in the delayed protection state; when the measured temperature ≥ temperature setting Value, the Work indicator is off, and the normally open contact of the relay is disconnected.
Refrigeration mode: When the measured temperature ≥ temperature set value + temperature difference set value, the Work indicator lights, the relay normally open contact is closed; the Work indicator flashes, indicating that the press is in the delayed protection state; when the measured temperature ≤ temperature setting Value, the Work indicator is off, and the normally open contact of the relay is disconnected.
System code, reason and action:
Sensor failure alarm: When the temperature probe circuit has a short circuit or open circuit failure, the thermostat activates the probe failure alarm mode and closes all execution states. The digital tube displays "LLL". After the failure is removed, press any key to return to normal working mode.
Over temperature limit alarm: When the temperature measurement exceeds the temperature measurement range, the thermostat starts the over temperature limit fault alarm mode, closes all execution states, the digital tube displays "HHH", when the temperature returns to the normal measurement range, press any key, Return to normal working mode.
DTC2210
Description:
Power supply voltage: AC110 ~ 230V
Temperature range: -40 ℃ ~ + 99 ℃
Temperature measurement accuracy: ± 1 ℃ (-40 ℃ ~ + 70 ℃)
Sensor line length: 100cm
Thermostat size: 93mm * 56mm * 34mm
Output capacity: cooling (10A / 250VAC) heating (10A / 250VAC)
Parameter setting method:
When the thermostat is working normally, press and hold the key for more than 3 seconds to enter the parameter modification mode, the digital tube displays the code of the first menu item "F1", press or to increase or decrease the code of the menu item, press and hold the key , Short press or key to increase or decrease and display the parameter setting value of the current menu; hold down the key, while long press or key to quickly increase or decrease and display the parameter setting value of the current menu.
At the same time, long-press the and keys to restore the parameters to the factory settings.
Operating instructions:
When the thermostat works normally, press and hold the power button for more than 3 seconds to turn off the thermostat. When the thermostat is off, press and hold the power button for more than 3 seconds to turn on the thermostat.
When the thermostat is working normally, the digital tube displays the current temperature measurement value, and performs automatic recognition and conversion of the cooling and heating working mode.
When the measured temperature ≥ temperature set value + temperature difference set value, enter the cooling state, the Cool indicator lights, the refrigeration relay normally open contact is closed; The Cool indicator flashes, indicating that the refrigeration equipment is in the state of delay protection of the press; when the temperature is measured ≤The temperature setting value, the Cool indicator is off, and the normally open contact of the cooling relay is disconnected.
When the measured temperature ≤ temperature set value-temperature difference set value enters the heating state, the Heat indicator lights, the heating relay normally open contact is closed; when the measured temperature ≥ temperature set value, the Heat indicator turns off, the heating relay normally open contact disconnect.
Cool indicator: On: cooling operation; off: cooling off; flashing: press delay
Heat indicator: On: heating work; off: heating off
note:Cool and Heat LEDs cannot be on at the same time
Repair system data:
After the thermostat is powered on, first check whether the parameter settings are correct. If an error is detected, "Er" is displayed. At this time, press any key to restore the default parameter settings and work normally. It is recommended to reset the parameters at this time.
System code, reason and action:
Sensor failure alarm: When the temperature probe circuit has a short circuit or open circuit failure, the thermostat activates the probe failure alarm mode and closes all execution states. The digital tube displays "EE". After the failure is removed, press any key to return to the normal working mode.
Over temperature limit alarm: When the temperature measurement exceeds the temperature measurement range, the thermostat activates the over temperature limit fault alarm mode, closes all execution states, the digital tube displays "HH", when the temperature returns to the normal measurement range, press any key, Return to normal working mode.
DTC3200
Description:
Power supply voltage: AC 110 ~ 230V
Power supply frequency: 50 / 60Hz
Temperature measurement range: -20 ~ 60 ℃
Humidity measurement range: 0% ~ 100% RH
Temperature measurement accuracy: 0.3 ℃
Humidity measurement accuracy: 3%
Output control: relay output
Output power: MAX 10A
Setting method: start value stop value (the program automatically determines the working mode to be cooling / dehumidifying mode)
Heating / cooling mode setting
Setting method: setting (starting temperature): long press the ▲ button, the starting temperature flashes, and the starting temperature value is set by the ▲ ▼ button
Setting (stop temperature): long press the ▼ button to stop the temperature flashing, set the stop temperature value by ▲ ▼ button
Heating use case: control the water heater, heating to 65 ℃ to stop, the temperature drops to 50 ℃ to start heating again
The first step: heating working mode, start temperature stop temperature
Step 2: Press and hold the ▲ button, the starting temperature flashes, and set the starting temperature to 30 ℃ via the ▲ ▼ button
Step 3: Press and hold the ▼ button to stop the temperature flashing, and set the stop temperature to 26 ° C with the ▲ ▼ button. The setting is complete!
Humidification / dehumidification mode settings:
Setting (Start Humidity): Long press the △ key, the start humidity value flashes, set the start humidity value by the △ ▽ key. Set [Stop Humidity]: Long press the △ key, stop the humidity value flashing, and set the stop humidity by the △ ▽ key value.
Examples of humidification: Fresh supermarket humidification, control humidifier 50% RH to start humidification, humidification to 80% RH to stop humidification.
Setup steps:
Step 1: Press and hold the △ key for 3 seconds to start the humidity value flashing, and set the start humidity value to 50% RH.
Step 2: Press and hold the ▽ key for 3 seconds to stop the humidity value flashing, set the value to 80% RH, the setting is completed, press the button for 5 seconds without operation, and automatically return to the normal display state
Dehumidification example: workshop control exhaust dehumidification system, humidity 70% RH starts dehumidification, humidity 40% RH stops dehumidification
Setup steps:
Step 1: Press and hold the △ key for 3 seconds to start the humidity value flashing, and set the start humidity value to 40% RH.
Step 2: Press and hold the ▽ key for 3 seconds to stop the humidity value from flashing, set the value to 70% RH, the setting is completed, press the button for 5 seconds without operation, and automatically return to the normal display state
Temperature correction:
Simultaneously press the ▲ ▼ key for 3 seconds to start the temperature digit flashing, and use the ▲ ▼ key to set the start temperature correction value; after the setting is completed, press the button for 5 seconds without operation, and automatically return to the normal display state.
Humidity correction:
Simultaneously press the △ ▽ key for 3 seconds to start the humidity digit flashing, and set the humidity correction value by the △ ▽ key; after the setting is completed, press the button for 5 seconds without operation, and it will automatically return to the normal display state.
DTC1201 DTC2201 thermostat
DTC1201 (2201) thermostat
Product name: Thermostat
Product model: DTC1201 (2201)
Power supply voltage: AC110 ~ 230V
Temperature range: -40 ℃ ~ + 99 ℃
Temperature measurement accuracy: ± 1 ℃ (-40 ℃ ~ + 70 ℃)
Sensor line length: 100cm
Thermostat size: 93mm * 56mm * 34mm
Output capacity: cooling (10A / 250VAC) heating (10A / 250VAC)
arameter setting method
When the thermostat is working normally, press and hold the s key for more than 3 seconds to enter the parameter modification mode, the "Set" indicator lights, the digital tube displays the code of the first menu item "F1", press the or key to increase or decrease the menu item Code, press the key to display the parameter setting value of the current menu, press and hold the key, then press or key to increase or decrease and display the parameter setting value of the current menu; press and hold the key, at the same time long press or key to quickly Increase or decrease and display the parameter setting value of the current menu.
Long press and keys at the same time, and then power on, the parameters will be restored to the factory settings.
Operating instructions
When the thermostat works normally, press and hold the power button for more than 3 seconds to turn off the thermostat. When the thermostat is off, press and hold the power button for more than 3 seconds to turn on the thermostat.
When the thermostat is working normally, the digital tube displays the current temperature measurement value, and performs automatic recognition and conversion of the cooling and heating working mode.
When the measured temperature ≥ temperature set value + temperature difference set value, enter the cooling state, the Cool indicator lights, the refrigeration relay normally open contact is closed; The Cool indicator flashes, indicating that the refrigeration equipment is in the state of delay protection of the press; when the temperature is measured ≤Temperature setting value, the Cool indicator is off, and the normally open contact of the cooling relay is disconnected.
When the measured temperature ≤ temperature set value-temperature difference set value enters the heating state, the Heat indicator lights, the heating relay normally open contact is closed; when the measured temperature ≥ temperature set value, the Heat indicator turns off, the heating relay normally open contact disconnect.
Repair system data
After the thermostat is powered on, first check whether the parameter settings are correct. If an error is detected, "Er" is displayed. At this time, pressing any key will restore the default parameter settings and work normally. It is recommended to reset the parameters at this time.
System code, reason and action
Sensor failure alarm: When the temperature probe circuit has a short circuit or open circuit failure, the thermostat activates the probe failure alarm mode and closes all execution states. The digital tube displays "EE". After the failure is removed, press any key to return to the normal working mode.
Over-temperature limit alarm: When the temperature measurement exceeds the temperature measurement range, the thermostat activates the over-temperature limit fault alarm mode, closes all execution states, the digital tube displays "HH", when the temperature returns to the normal measurement range, press any key, Return to normal working mode. (18b20)

Tax excluded, add at checkout if applicable
Color:
Quantity
Service commitment
Shipping: ₦12,375
16 - 30 days
Return & Refund
7-day return window
Secure Payment
Buyer protection guaranteed
AC 110V 220V Digital Temperature Controller DTC1200 Thermostat Thermoregulator Sensor Meter For Incubator Cooling Heating Fridge
Package Include:
Type 1
1 x DTC1200 Intellligent Temperature Controller
1 x NTC 10K B3950 Temperature sensor
Type 2
1 x DTC1100 Intellligent Temperature Controller
1 x NTC 10K B3950 Temperature sensor
Type 3
1 x DTC2200 Intellligent Temperature Controller
1 x DS18B20 Temperature sensor
Type 4
1 x DTC1110 Intellligent Temperature Controller
1 x NTC 10K B3950 Temperature sensor
Type 5
1 x DTC2210 Intellligent Temperature Controller
1 x DS18B20 Temperature sensor
Type 6
1 x DTC3200 Intellligent Temperature Humidity Controller
1 x SHT20 Temperature sensor
Type 7
1 x DTC1201 WIFI Intellligent Temperature Controller
1 x NTC 10K B3950 Temperature sensor
1 x WIFI Antenna
1 x User Manual
Type 8
1 x DTC2201 WIFI Intellligent Temperature Controller
1 x DS18B20 Temperature sensor
1 x WIFI Antenna
1 x User Manual
DTC1200
Description:
Product Name: Thermostat
Product model: DTC1200
Supply voltage: AC110~230V
Temperature range: -40°C~+99°C
Temperature measurement accuracy: ±1 °C (-40 °C ~ +70 °C)
Sensor line length: 100cm
Thermostat size: 93mm*56mm*34mm
Output capacity: cooling (compressor 3A) heating (10A/250VAC)
View parameter methods:
When the thermostat is working normally, press and release the key once to display the temperature setting value; press and release the key once to display the temperature difference setting value. After 3 seconds, the temperature returns to the normal display state.
Set the parameter method:
When the thermostat is working normally, press and hold the S button for more than 3 seconds to enter the modified parameter mode. The "Set" indicator lights up, the digital tube displays the code "F1" of the first menu item, and press the up or down button to increase or decrease the value. The code of the menu item, press S key to display the parameter setting value of the current menu, press and hold the S key, then press the up or down key to increase or decrease the parameter setting value of the current menu; press and hold the S key Do not hold, while long press the up or down button to quickly up or down and display the parameter settings of the current menu.
Press and hold the up and down keys at the same time to restore the parameters to the factory settings.
Operating instructions:
When the thermostat is working normally, press and hold the power button for more than 3 seconds to turn off the thermostat. When the thermostat is off, press and hold the power button for more than 3 seconds to open the thermostat.
When the thermostat is working normally, the digital tube displays the current temperature measurement value, and performs automatic recognition conversion of the cooling heating operation mode.
When the measured temperature ≥ temperature set value + temperature difference set value, enter the cooling state, the Cool indicator light is on, the cooling relay normally open contact is closed; the Cool indicator flashes, indicating that the cooling device is in the press delay protection state; when measuring the temperature ≤ temperature set value, the Cool indicator is off, and the normally open contact of the refrigeration relay is disconnected.
When the measured temperature ≤ temperature set value - temperature difference set value enters the heating state, the Heat indicator light is on, the heating relay normally open contact is closed; when the measured temperature ≥ temperature set value, the Heat indicator is off, the heating relay normally open contact disconnect.
Repair system data:
After the thermostat is powered on, first check whether the parameter settings are correct. If an error is detected, "Er" is displayed. Pressing any key will restore the default parameter settings and work normally. It is recommended to reset the parameters at this time.
System code, reason and action:
Sensor fault alarm: When the temperature probe loop is short-circuited or open-circuit fault, the thermostat starts the probe fault alarm mode, closes all execution states, and the digital tube displays "EE". After the fault is cleared, press any key to return to the normal working mode.
Over-temperature alarm: When the temperature measurement exceeds the temperature measurement range, the thermostat starts the over-temperature limit fault alarm mode, and all execution states are turned off. The digital tube displays "HH". When the temperature returns to the normal measurement range, press any key. Return to normal working mode.
DTC1100
Description:
Power supply voltage: AC110 ~ 220V
Temperature range: -40 ℃ ~ + 99 ℃
Temperature measurement accuracy: ± 1 ℃ (-40 ℃ ~ + 70 ℃)
Sensor line length: 100cm
Thermostat size: 93mm * 56mm * 34mm
Output capacity: cooling (10A / 250VAC) heating (10A / 250VAC)
Parameter setting method:
When the thermostat works normally, short press the button, the set temperature value flashes, modify the set temperature parameter by either long press or short press; press and hold the key for more than 3 seconds to enter the parameter modification mode, the digital tube displays the first menu item Code "HC", press or key to increase or decrease the code of the menu item, press the key to display the parameter setting value of the current menu, short press or key to increase or decrease and display the parameter setting value of the current menu.
Press and hold the button to restore the parameters to the factory settings.
Operating instructions:
When the thermostat is working normally, press and hold the power button for more than 3 seconds to turn off the thermostat. When the thermostat is off, short press the power button to turn on the thermostat.
When the thermostat works normally, the digital tube displays the current temperature measurement value.
First set the temperature control working state, heating or cooling.
Heating mode: When the measured temperature ≤ temperature set value-temperature difference set value, the Work indicator lights, the relay normally open contact closes; the Work indicator flashes, indicating that the press is in the delayed protection state; when the measured temperature ≥ temperature setting Value, the Work indicator is off, and the normally open contact of the relay is disconnected.
Refrigeration mode: When the measured temperature ≥ temperature set value + temperature difference set value, the Work indicator lights, the relay normally open contact is closed; the Work indicator flashes, indicating that the press is in the delayed protection state; when the measured temperature ≤ temperature setting Value, the Work indicator is off, and the normally open contact of the relay is disconnected.
System code, reason and action:
Sensor failure alarm: When the temperature probe circuit has a short circuit or open circuit failure, the thermostat activates the probe failure alarm mode and closes all execution states. The digital tube displays "LLL". After the failure is removed, press any key to return to normal working mode.
Over temperature limit alarm: When the temperature measurement exceeds the temperature measurement range, the thermostat starts the over temperature limit fault alarm mode, closes all execution states, the digital tube displays "HHH", when the temperature returns to the normal measurement range, press any key, Return to normal working mode.
DTC2200
Description:
Power supply voltage: AC110 ~ 230V
Temperature range: -40 ℃ ~ + 99 ℃
Temperature measurement accuracy: ± 1 ℃ (-40 ℃ ~ + 70 ℃)
Sensor line length: 100cm
Thermostat size: 93mm * 56mm * 34mm
Output capacity: cooling (10A / 250VAC) heating (10A / 250VAC)
Parameter setting method:
When the thermostat is working normally, press and hold the key for more than 3 seconds to enter the parameter modification mode, the digital tube displays the code of the first menu item "F1", press or to increase or decrease the code of the menu item, press and hold the key , Short press or key to increase or decrease and display the parameter setting value of the current menu; hold down the key, while long press or key to quickly increase or decrease and display the parameter setting value of the current menu.
At the same time, long-press the and keys to restore the parameters to the factory settings.
Operating instructions:
When the thermostat works normally, press and hold the power button for more than 3 seconds to turn off the thermostat. When the thermostat is off, press and hold the power button for more than 3 seconds to turn on the thermostat.
When the thermostat is working normally, the digital tube displays the current temperature measurement value, and performs automatic recognition and conversion of the cooling and heating working mode.
When the measured temperature ≥ temperature set value + temperature difference set value, enter the cooling state, the Cool indicator lights, the refrigeration relay normally open contact is closed; The Cool indicator flashes, indicating that the refrigeration equipment is in the state of delay protection of the press; when the temperature is measured ≤The temperature setting value, the Cool indicator is off, and the normally open contact of the cooling relay is disconnected.
When the measured temperature ≤ temperature set value-temperature difference set value enters the heating state, the Heat indicator lights, the heating relay normally open contact is closed; when the measured temperature ≥ temperature set value, the Heat indicator turns off, the heating relay normally open contact disconnect.
Cool indicator: On: cooling operation; off: cooling off; flashing: press delay
Heat indicator: On: heating work; off: heating off
Set indicator on: parameter setting status
note:Cool and Heat LEDs cannot be on at the same time
Repair system data:
After the thermostat is powered on, first check whether the parameter settings are correct. If an error is detected, "Er" is displayed. At this time, press any key to restore the default parameter settings and work normally. It is recommended to reset the parameters at this time.
System code, reason and action:
Sensor failure alarm: When the temperature probe circuit has a short circuit or open circuit failure, the thermostat activates the probe failure alarm mode and closes all execution states. The digital tube displays "EE". After the failure is removed, press any key to return to the normal working mode.
Over temperature limit alarm: When the temperature measurement exceeds the temperature measurement range, the thermostat activates the over temperature limit fault alarm mode, closes all execution states, the digital tube displays "HH", when the temperature returns to the normal measurement range, press any key, Return to normal working mode.
DTC1110
Description:
Power supply voltage: AC110 ~ 220V
Temperature range: -40 ℃ ~ + 99 ℃
Temperature measurement accuracy: ± 1 ℃ (-40 ℃ ~ + 70 ℃)
Sensor line length: 100cm
Thermostat size: 93mm * 56mm * 34mm
Output capacity: cooling (10A / 250VAC) heating (10A / 250VAC)
Parameter setting method:
When the thermostat works normally, short press the button, the set temperature value flashes, modify the set temperature parameter by either long press or short press; press and hold the key for more than 3 seconds to enter the parameter modification mode, the digital tube displays the first menu item Code "HC", press or key to increase or decrease the code of the menu item, press the key to display the parameter setting value of the current menu, short press or key to increase or decrease and display the parameter setting value of the current menu.
Press and hold the button to restore the parameters to the factory settings.
Operating instructions:
When the thermostat is working normally, press and hold the power button for more than 3 seconds to turn off the thermostat. When the thermostat is off, short press the power button to turn on the thermostat.
When the thermostat works normally, the digital tube displays the current temperature measurement value.
First set the temperature control working state, heating or cooling.
Heating mode: When the measured temperature ≤ temperature set value-temperature difference set value, the Work indicator lights, the relay normally open contact closes; the Work indicator flashes, indicating that the press is in the delayed protection state; when the measured temperature ≥ temperature setting Value, the Work indicator is off, and the normally open contact of the relay is disconnected.
Refrigeration mode: When the measured temperature ≥ temperature set value + temperature difference set value, the Work indicator lights, the relay normally open contact is closed; the Work indicator flashes, indicating that the press is in the delayed protection state; when the measured temperature ≤ temperature setting Value, the Work indicator is off, and the normally open contact of the relay is disconnected.
System code, reason and action:
Sensor failure alarm: When the temperature probe circuit has a short circuit or open circuit failure, the thermostat activates the probe failure alarm mode and closes all execution states. The digital tube displays "LLL". After the failure is removed, press any key to return to normal working mode.
Over temperature limit alarm: When the temperature measurement exceeds the temperature measurement range, the thermostat starts the over temperature limit fault alarm mode, closes all execution states, the digital tube displays "HHH", when the temperature returns to the normal measurement range, press any key, Return to normal working mode.
DTC2210
Description:
Power supply voltage: AC110 ~ 230V
Temperature range: -40 ℃ ~ + 99 ℃
Temperature measurement accuracy: ± 1 ℃ (-40 ℃ ~ + 70 ℃)
Sensor line length: 100cm
Thermostat size: 93mm * 56mm * 34mm
Output capacity: cooling (10A / 250VAC) heating (10A / 250VAC)
Parameter setting method:
When the thermostat is working normally, press and hold the key for more than 3 seconds to enter the parameter modification mode, the digital tube displays the code of the first menu item "F1", press or to increase or decrease the code of the menu item, press and hold the key , Short press or key to increase or decrease and display the parameter setting value of the current menu; hold down the key, while long press or key to quickly increase or decrease and display the parameter setting value of the current menu.
At the same time, long-press the and keys to restore the parameters to the factory settings.
Operating instructions:
When the thermostat works normally, press and hold the power button for more than 3 seconds to turn off the thermostat. When the thermostat is off, press and hold the power button for more than 3 seconds to turn on the thermostat.
When the thermostat is working normally, the digital tube displays the current temperature measurement value, and performs automatic recognition and conversion of the cooling and heating working mode.
When the measured temperature ≥ temperature set value + temperature difference set value, enter the cooling state, the Cool indicator lights, the refrigeration relay normally open contact is closed; The Cool indicator flashes, indicating that the refrigeration equipment is in the state of delay protection of the press; when the temperature is measured ≤The temperature setting value, the Cool indicator is off, and the normally open contact of the cooling relay is disconnected.
When the measured temperature ≤ temperature set value-temperature difference set value enters the heating state, the Heat indicator lights, the heating relay normally open contact is closed; when the measured temperature ≥ temperature set value, the Heat indicator turns off, the heating relay normally open contact disconnect.
Cool indicator: On: cooling operation; off: cooling off; flashing: press delay
Heat indicator: On: heating work; off: heating off
note:Cool and Heat LEDs cannot be on at the same time
Repair system data:
After the thermostat is powered on, first check whether the parameter settings are correct. If an error is detected, "Er" is displayed. At this time, press any key to restore the default parameter settings and work normally. It is recommended to reset the parameters at this time.
System code, reason and action:
Sensor failure alarm: When the temperature probe circuit has a short circuit or open circuit failure, the thermostat activates the probe failure alarm mode and closes all execution states. The digital tube displays "EE". After the failure is removed, press any key to return to the normal working mode.
Over temperature limit alarm: When the temperature measurement exceeds the temperature measurement range, the thermostat activates the over temperature limit fault alarm mode, closes all execution states, the digital tube displays "HH", when the temperature returns to the normal measurement range, press any key, Return to normal working mode.
DTC3200
Description:
Power supply voltage: AC 110 ~ 230V
Power supply frequency: 50 / 60Hz
Temperature measurement range: -20 ~ 60 ℃
Humidity measurement range: 0% ~ 100% RH
Temperature measurement accuracy: 0.3 ℃
Humidity measurement accuracy: 3%
Output control: relay output
Output power: MAX 10A
Setting method: start value stop value (the program automatically determines the working mode to be cooling / dehumidifying mode)
Heating / cooling mode setting
Setting method: setting (starting temperature): long press the ▲ button, the starting temperature flashes, and the starting temperature value is set by the ▲ ▼ button
Setting (stop temperature): long press the ▼ button to stop the temperature flashing, set the stop temperature value by ▲ ▼ button
Heating use case: control the water heater, heating to 65 ℃ to stop, the temperature drops to 50 ℃ to start heating again
The first step: heating working mode, start temperature stop temperature
Step 2: Press and hold the ▲ button, the starting temperature flashes, and set the starting temperature to 30 ℃ via the ▲ ▼ button
Step 3: Press and hold the ▼ button to stop the temperature flashing, and set the stop temperature to 26 ° C with the ▲ ▼ button. The setting is complete!
Humidification / dehumidification mode settings:
Setting (Start Humidity): Long press the △ key, the start humidity value flashes, set the start humidity value by the △ ▽ key. Set [Stop Humidity]: Long press the △ key, stop the humidity value flashing, and set the stop humidity by the △ ▽ key value.
Examples of humidification: Fresh supermarket humidification, control humidifier 50% RH to start humidification, humidification to 80% RH to stop humidification.
Setup steps:
Step 1: Press and hold the △ key for 3 seconds to start the humidity value flashing, and set the start humidity value to 50% RH.
Step 2: Press and hold the ▽ key for 3 seconds to stop the humidity value flashing, set the value to 80% RH, the setting is completed, press the button for 5 seconds without operation, and automatically return to the normal display state
Dehumidification example: workshop control exhaust dehumidification system, humidity 70% RH starts dehumidification, humidity 40% RH stops dehumidification
Setup steps:
Step 1: Press and hold the △ key for 3 seconds to start the humidity value flashing, and set the start humidity value to 40% RH.
Step 2: Press and hold the ▽ key for 3 seconds to stop the humidity value from flashing, set the value to 70% RH, the setting is completed, press the button for 5 seconds without operation, and automatically return to the normal display state
Temperature correction:
Simultaneously press the ▲ ▼ key for 3 seconds to start the temperature digit flashing, and use the ▲ ▼ key to set the start temperature correction value; after the setting is completed, press the button for 5 seconds without operation, and automatically return to the normal display state.
Humidity correction:
Simultaneously press the △ ▽ key for 3 seconds to start the humidity digit flashing, and set the humidity correction value by the △ ▽ key; after the setting is completed, press the button for 5 seconds without operation, and it will automatically return to the normal display state.
DTC1201 DTC2201 thermostat
DTC1201 (2201) thermostat
Product name: Thermostat
Product model: DTC1201 (2201)
Power supply voltage: AC110 ~ 230V
Temperature range: -40 ℃ ~ + 99 ℃
Temperature measurement accuracy: ± 1 ℃ (-40 ℃ ~ + 70 ℃)
Sensor line length: 100cm
Thermostat size: 93mm * 56mm * 34mm
Output capacity: cooling (10A / 250VAC) heating (10A / 250VAC)
arameter setting method
When the thermostat is working normally, press and hold the s key for more than 3 seconds to enter the parameter modification mode, the "Set" indicator lights, the digital tube displays the code of the first menu item "F1", press the or key to increase or decrease the menu item Code, press the key to display the parameter setting value of the current menu, press and hold the key, then press or key to increase or decrease and display the parameter setting value of the current menu; press and hold the key, at the same time long press or key to quickly Increase or decrease and display the parameter setting value of the current menu.
Long press and keys at the same time, and then power on, the parameters will be restored to the factory settings.
Operating instructions
When the thermostat works normally, press and hold the power button for more than 3 seconds to turn off the thermostat. When the thermostat is off, press and hold the power button for more than 3 seconds to turn on the thermostat.
When the thermostat is working normally, the digital tube displays the current temperature measurement value, and performs automatic recognition and conversion of the cooling and heating working mode.
When the measured temperature ≥ temperature set value + temperature difference set value, enter the cooling state, the Cool indicator lights, the refrigeration relay normally open contact is closed; The Cool indicator flashes, indicating that the refrigeration equipment is in the state of delay protection of the press; when the temperature is measured ≤Temperature setting value, the Cool indicator is off, and the normally open contact of the cooling relay is disconnected.
When the measured temperature ≤ temperature set value-temperature difference set value enters the heating state, the Heat indicator lights, the heating relay normally open contact is closed; when the measured temperature ≥ temperature set value, the Heat indicator turns off, the heating relay normally open contact disconnect.
Repair system data
After the thermostat is powered on, first check whether the parameter settings are correct. If an error is detected, "Er" is displayed. At this time, pressing any key will restore the default parameter settings and work normally. It is recommended to reset the parameters at this time.
System code, reason and action
Sensor failure alarm: When the temperature probe circuit has a short circuit or open circuit failure, the thermostat activates the probe failure alarm mode and closes all execution states. The digital tube displays "EE". After the failure is removed, press any key to return to the normal working mode.
Over-temperature limit alarm: When the temperature measurement exceeds the temperature measurement range, the thermostat activates the over-temperature limit fault alarm mode, closes all execution states, the digital tube displays "HH", when the temperature returns to the normal measurement range, press any key, Return to normal working mode. (18b20)
| Category | Smart Thermostats |
|---|---|
| Color options | DTC1200 red, DTC1110 red blue, DTC2210 red blue, DTC3200 red blue, DTC1201 WiFi red, DTC2201 WiFi red |
| Brand Name | Dmyond |
| Battery Included | no |
| High-concerned chemical | None |
| Origin | Mainland China |
| Semi-finishedproduct | No |
| Cable Length | 1m |
| Use | Indoor |
| Certification | CE |
| Display Size | 1.9 Inches & Under |
| Is Smart Device | Yes |
| Item | microcomputer temperature controller |
| Item 1 | aquarium temperature controller |
| Item 2 | replace stc 1000 temperature controller |
| Item 3 | 220v digital led temperature controller 10a |
| Item 4 | digital led temperature controller 10a thermoter |
| Feature | digital led temperature controller thermo |
| Thermostat size: | 93mm * 56mm * 34mm |
| Output capacity: | cooling (10A / 250VAC) heating (10A / 250VAC) |
| Sensor line length: | 100cm |
| Supply voltage: | AC110~230V |
No questions yet. Ask about size, compatibility, delivery or anything else.