ORP Redox Potentiometer, Modular Redox Sensor, Water Quality Testing for Arduino
4.6(13 reviews)Your money is held until you receive your order, plus 7 days to report a problem. Refund if it never arrives or is not as described. Payments go through secure, licensed providers (Paystack, OPay).
14 - 26 days
Ships by express courier. Delivery times are estimates and may vary based on customs clearance.
7-day return window
Item must be unused and in original packaging.
Refund via: Original payment method
Warranty: no manufacturer warranty unless the description says so. Faulty, damaged or not-as-described items are covered by our 7-day buyer protection.
ORP Sensor Module Product InformationFirst, product overviewOxidation-Reduction Potential (ORP) is a key indicator for measuring redox capacity, expressed in mV. The higher the ORP value, the stronger the oxidation; conversely, the stronger the reduction. In the field of water quality testing, ORP i...
ORP Sensor Module Product Information
First, product overview
Oxidation-Reduction Potential (ORP) is a key indicator for measuring redox capacity, expressed in mV. The higher the ORP value, the stronger the oxidation; conversely, the stronger the reduction. In the field of water quality testing, ORP is an extremely important comprehensive indicator that can reflect the status of redox substances in water bodies and help people understand the state of water quality.
The wiring and use method of this ORP sensor module are simple and easy to understand. After connecting the circuit, the ORP value of the solution can be measured by program control. The measuring element adopts an ORP composite electrode, which is composed of a gold or platinum electrode and a reference electrode. It is used to accurately measure the redox potential of the solution.
Second, technical parameters
Power supply: + 5.00V, the closer the power supply voltage is to this value, the higher the measurement accuracy.
Measurement range: -2000mV - 2000mV, which can meet the needs of redox potential measurement in various scenarios.
Output voltage range: 0 - 4V, output measurement results in the form of analog signals.
Measurement temperature: 5 - 70 ° C, can work normally in this temperature range.
Measurement accuracy: ± 10mV (25 ° C), ensuring high measurement accuracy at standard temperatures.
Response time: ≤ 20sec, can quickly respond to the change of solution redox potential.
Stability time: ≤ 1min, allowing the measurement results to reach a stable state in a relatively short time.
ORP potentiometer interface: BNC interface is adopted to facilitate connection with ORP electrodes.
Module size: 35mm × 26mm, compact size, easy to install and integrate.
Three, pin description
The module has three pins. The VCC pin is the positive electrode of the power supply voltage, which needs to be connected to a 5V voltage, and 3.3V cannot be used; the GND pin is the negative electrode of the power supply voltage; the AO pin is the analog signal output pin, and the output voltage range is 0-4V.
Four, the use of methods
First, connect the ORP sensor module to the processor, and do not connect the ORP potentiometer for the time being.
Burn calibration routines to prepare for accurate measurement.
Open the serial port debugging assistant and view the current printed ORP value. Press the zero calibration button on the module to get the offset. Change the "A & dline OFFSET 0 & rdquo; in the program to" A & dline OFFSET [measurement value] & rdquo;, recompile and download the program to eliminate the zero drift caused by the operation amplification and improve the measurement accuracy.
Connect the ORP electrode to the BNC interface of the ORP sensor module, and burn the corrected program to measure the ORP value of the solution.
Five, matters needing attention
Make sure that the power supply voltage of the ORP module is close to + 5.00V to ensure the measurement accuracy.
ORP electrodes usually do not require calibration and can be used directly. If there is any doubt about the quality of the electrode or the test results, the electrode potential can be checked with the ORP standard solution to determine the performance of the electrode or instrument.
After each measurement of a solution, the ORP electrode should be cleaned with water. It is recommended to use deionized water to avoid the residual solution affecting the subsequent measurement.
When the ORP electrode is connected to the ORP module, it is strictly forbidden to press the calibration button to prevent damage to the equipment or affect the measurement accuracy.
As the solution temperature increases, the ORP value will decrease significantly, and the two have a good linear relationship. Therefore, when measuring the solution ORP value, the current solution temperature must be indicated for the measurement results to be practical.

Tax excluded, add at checkout if applicable
Color:
Quantity
Service commitment
Shipping: ₦10,902
14 - 26 days
Return & Refund
7-day return window
Secure Payment
Buyer protection guaranteed
ORP Sensor Module Product Information
First, product overview
Oxidation-Reduction Potential (ORP) is a key indicator for measuring redox capacity, expressed in mV. The higher the ORP value, the stronger the oxidation; conversely, the stronger the reduction. In the field of water quality testing, ORP is an extremely important comprehensive indicator that can reflect the status of redox substances in water bodies and help people understand the state of water quality.
The wiring and use method of this ORP sensor module are simple and easy to understand. After connecting the circuit, the ORP value of the solution can be measured by program control. The measuring element adopts an ORP composite electrode, which is composed of a gold or platinum electrode and a reference electrode. It is used to accurately measure the redox potential of the solution.
Second, technical parameters
Power supply: + 5.00V, the closer the power supply voltage is to this value, the higher the measurement accuracy.
Measurement range: -2000mV - 2000mV, which can meet the needs of redox potential measurement in various scenarios.
Output voltage range: 0 - 4V, output measurement results in the form of analog signals.
Measurement temperature: 5 - 70 ° C, can work normally in this temperature range.
Measurement accuracy: ± 10mV (25 ° C), ensuring high measurement accuracy at standard temperatures.
Response time: ≤ 20sec, can quickly respond to the change of solution redox potential.
Stability time: ≤ 1min, allowing the measurement results to reach a stable state in a relatively short time.
ORP potentiometer interface: BNC interface is adopted to facilitate connection with ORP electrodes.
Module size: 35mm × 26mm, compact size, easy to install and integrate.
Three, pin description
The module has three pins. The VCC pin is the positive electrode of the power supply voltage, which needs to be connected to a 5V voltage, and 3.3V cannot be used; the GND pin is the negative electrode of the power supply voltage; the AO pin is the analog signal output pin, and the output voltage range is 0-4V.
Four, the use of methods
First, connect the ORP sensor module to the processor, and do not connect the ORP potentiometer for the time being.
Burn calibration routines to prepare for accurate measurement.
Open the serial port debugging assistant and view the current printed ORP value. Press the zero calibration button on the module to get the offset. Change the "A & dline OFFSET 0 & rdquo; in the program to" A & dline OFFSET [measurement value] & rdquo;, recompile and download the program to eliminate the zero drift caused by the operation amplification and improve the measurement accuracy.
Connect the ORP electrode to the BNC interface of the ORP sensor module, and burn the corrected program to measure the ORP value of the solution.
Five, matters needing attention
Make sure that the power supply voltage of the ORP module is close to + 5.00V to ensure the measurement accuracy.
ORP electrodes usually do not require calibration and can be used directly. If there is any doubt about the quality of the electrode or the test results, the electrode potential can be checked with the ORP standard solution to determine the performance of the electrode or instrument.
After each measurement of a solution, the ORP electrode should be cleaned with water. It is recommended to use deionized water to avoid the residual solution affecting the subsequent measurement.
When the ORP electrode is connected to the ORP module, it is strictly forbidden to press the calibration button to prevent damage to the equipment or affect the measurement accuracy.
As the solution temperature increases, the ORP value will decrease significantly, and the two have a good linear relationship. Therefore, when measuring the solution ORP value, the current solution temperature must be indicated for the measurement results to be practical.
| Category | Potentiometers |
|---|---|
| Color options | ORP Module, ORP Electrode, ORP Industrial Elect, Module Electrode, ORP Module Industria |
| Brand Name | NONE |
| High-concerned chemical | None |
| Origin | Mainland China |
| Working principle | voltage sensor |
| Sensor category | Sensor set |
| Material | mixture |
| Output model category | Analog sensor |
| Applicable scenario | Aquatic products, water quality testing, industrial, commercial |
No questions yet. Ask about size, compatibility, delivery or anything else.
Sign in to ask a question.