Modbus RTU 4-Channel Load Cell Amplifier High-Speed AD Sampling 10Hz–1280Hz Stable Output for PLC Automation Systems
5.0(11 reviews)Your money is held until you receive your order, plus 7 days to report a problem. Refund if it never arrives or is not as described. Payments go through secure, licensed providers (Paystack, OPay).
14 - 26 days
Ships by express courier. Delivery times are estimates and may vary based on customs clearance.
7-day return window
Item must be unused and in original packaging.
Refund via: Original payment method
Warranty: no manufacturer warranty unless the description says so. Faulty, damaged or not-as-described items are covered by our 7-day buyer protection.
ParameterSpecificationPower Supply10–28V DC, <2WOperating CurrentDepends on connected sensors, max drive 500mAChannels2–4 load cell inputsSensor Excitation5V DC ±3%Sensor DriveUp to 4 × 350Ω sensors per channelInput Signal Range0 to ±30 mVResolution1/500000Sampling Rates10Hz, 40Hz, 640Hz, 1280Hz (se...
Parameter
Specification
Power Supply
10–28V DC, <2W
Operating Current
Depends on connected sensors, max drive 500mA
Channels
2–4 load cell inputs
Sensor Excitation
5V DC ±3%
Sensor Drive
Up to 4 × 350Ω sensors per channel
Input Signal Range
0 to ±30 mV
Resolution
1/500000
Sampling Rates
10Hz, 40Hz, 640Hz, 1280Hz (selectable)
ADC Type
Sigma-Delta
Communication
RS485, Modbus RTU, Function Codes 03/06/16
Baud Rates
2400–600000 bps (configurable via DIP or software)
Slave Address
1–255, broadcast = 254
Isolation & Protection
Optical isolation, power isolation, surge protection
Operating Temp
–40 to +85°C
Humidity
0–95% RH (non-condensing)
Protection Level
IP65
Mounting
DIN rail or fixed mounting
Weight
~250g
Communication Interface
The transmitter provides RS485 communication with standard Modbus RTU protocol , ensuring compatibility with PLCs, DCS, and industrial PCs.
Specifications:
Item
Specification
Interface
RS485 (2-wire differential)
Protocol
Modbus RTU
Supported Function Codes
03 (Read), 06 (Write Single Register), 16 (Write Multiple Registers)
Baud Rate Options
2400, 4800, 9600, 19200, 28800, 38400, 57600, 115200, 128000, 230400, 256000, 460800, 500000, 512000, 600000 bps
Slave Address (software)
1–255 (default = 1), broadcast = 254
Slave Address (DIP)
0–15 (DIP switch configuration)
Default Settings
Baud rate: 115200, Data bits: 8, Stop bit: 1, Parity: None, Address: 1, Byte order: Little-endian (2143)
RS485 Cabling:
Maximum distance: up to 1200 m at 9600 bps .
For short-distance debugging, ordinary cables are acceptable. For longer runs, use shielded twisted pair cables .
For multi-drop connections, connect a 120Ω termination resistor across A and B at the end of the line.
Indicators & Reset:
P (Power): Always ON when powered.
G (Comm): Blinks during communication (frequency depends on baud rate).
T (TX): Blinks when transmitting.
R (RX): Blinks when receiving.
Reset button: Hold >3s to restore factory defaults (⚠ clears calibration data).

Tax excluded, add at checkout if applicable
Color:
Quantity
Service commitment
Free Delivery
14 - 26 days
Return & Refund
7-day return window
Secure Payment
Buyer protection guaranteed
Parameter
Specification
Power Supply
10–28V DC, <2W
Operating Current
Depends on connected sensors, max drive 500mA
Channels
2–4 load cell inputs
Sensor Excitation
5V DC ±3%
Sensor Drive
Up to 4 × 350Ω sensors per channel
Input Signal Range
0 to ±30 mV
Resolution
1/500000
Sampling Rates
10Hz, 40Hz, 640Hz, 1280Hz (selectable)
ADC Type
Sigma-Delta
Communication
RS485, Modbus RTU, Function Codes 03/06/16
Baud Rates
2400–600000 bps (configurable via DIP or software)
Slave Address
1–255, broadcast = 254
Isolation & Protection
Optical isolation, power isolation, surge protection
Operating Temp
–40 to +85°C
Humidity
0–95% RH (non-condensing)
Protection Level
IP65
Mounting
DIN rail or fixed mounting
Weight
~250g
Communication Interface
The transmitter provides RS485 communication with standard Modbus RTU protocol , ensuring compatibility with PLCs, DCS, and industrial PCs.
Specifications:
Item
Specification
Interface
RS485 (2-wire differential)
Protocol
Modbus RTU
Supported Function Codes
03 (Read), 06 (Write Single Register), 16 (Write Multiple Registers)
Baud Rate Options
2400, 4800, 9600, 19200, 28800, 38400, 57600, 115200, 128000, 230400, 256000, 460800, 500000, 512000, 600000 bps
Slave Address (software)
1–255 (default = 1), broadcast = 254
Slave Address (DIP)
0–15 (DIP switch configuration)
Default Settings
Baud rate: 115200, Data bits: 8, Stop bit: 1, Parity: None, Address: 1, Byte order: Little-endian (2143)
RS485 Cabling:
Maximum distance: up to 1200 m at 9600 bps .
For short-distance debugging, ordinary cables are acceptable. For longer runs, use shielded twisted pair cables .
For multi-drop connections, connect a 120Ω termination resistor across A and B at the end of the line.
Indicators & Reset:
P (Power): Always ON when powered.
G (Comm): Blinks during communication (frequency depends on baud rate).
T (TX): Blinks when transmitting.
R (RX): Blinks when receiving.
Reset button: Hold >3s to restore factory defaults (⚠ clears calibration data).
No questions yet. Ask about size, compatibility, delivery or anything else.
Sign in to ask a question.
| Category | Repair Parts |
|---|---|
| Color options | 1PCS, 2PCS, 3PCS, 5PCS |
| Brand Name | BENGBUZZYQ |
| High-concerned chemical | None |
| Origin | Mainland China |
| Output | Digital Sensor |
| Theory | Resistance Sensor |
| Type | Optical-Electronics Sensor |
| Is_customized | Yes |
| Use | Pressure Sensor |
| Material | Polymer |
| Power Supply | 10-28V DC |
| Power Consumption | < 2W |
| Operating Current | Depends on sensors; drive capacity 500 mA |
| Operating Temperature | -40~85°C |
| Humidity | 0-95% RH, non-condensing |
| Protection Level | IP65 |
| Excitation Voltage | 5VDC ±3% |
| Channels | 2-4 load cell inputs |
| Resolution | 1/500,000 |
| Sampling Rates | 10Hz, 40Hz, 640Hz, 1280Hz |
| Communication Interface | RS485, Modbus RTU, Function Codes 03/06/16 |