LiitoKala Lii-500 Universal LCD Smart Charger for Li-ion Ni-MH AA AAA 10440 14500 16340 17500 18650 Battery Capacity Test
5.0(9 reviews)Your money is held until you receive your order, plus 7 days to report a problem. Refund if it never arrives or is not as described. Payments go through secure, licensed providers (Paystack, OPay).
12 - 21 days
Ships by express courier. Delivery times are estimates and may vary based on customs clearance.
7-day return window
Item must be unused and in original packaging.
Refund via: Original payment method
Warranty: no manufacturer warranty unless the description says so. Faulty, damaged or not-as-described items are covered by our 7-day buyer protection.
⚠️ IMPORTANT – This version (Lii-500 noother) does NOT include a power adapterThis sales package is the charger unit + manual only – the DC 12V/2A power adapter is NOT included. You must prepare a compatible adapter (DC 12V/2A output, centre‑positive, 5.5×2.1mm barrel plug) separately; otherwise the...
⚠️ IMPORTANT – This version (Lii-500 noother) does NOT include a power adapter
This sales package is the charger unit + manual only – the DC 12V/2A power adapter is NOT included . You must prepare a compatible adapter (DC 12V/2A output, centre‑positive, 5.5×2.1mm barrel plug) separately; otherwise the charger cannot operate.
If you prefer a bundled adapter, please choose the standard version (with adapter).
LiitoKala Lii-500 Smart Charger – Capacity Testing · Internal Resistance Measurement · 4‑Channel Independent (No Adapter Version)
⚠️ Important Notes – Read Before Use
This charger features internal resistance measurement – it will test and display the internal resistance (in mΩ) of each battery about 3 seconds after insertion, giving you a quick reference on battery health.
All displayed data (voltage, current, capacity, time, internal resistance) are for reference only and are not professional laboratory measurements. For precise battery parameters, please use dedicated testing instruments.
This charger is designed only for:
1.2V Ni‑MH batteries (AA, AAA, etc.)
3.7V cylindrical Li‑ion batteries (18650, 26650, 14500, etc.)
DO NOT charge :
1.5V primary lithium batteries (non‑rechargeable)
3.2V LiFePO₄ batteries
3.8V IMR (high‑voltage) Li‑ion batteries
Charging any of these types may cause damage or safety hazards – always check the nominal voltage on your battery!
The charger may become warm during operation – this is normal. Avoid burns. Unplug the power and remove batteries after use.
For indoor use only. A DC 12V/2A power adapter is required (this version does NOT include one – please supply your own).
🔍 Capacity Testing & Internal Resistance – Three Modes for Full Battery Assessment
The Lii‑500 not only charges batteries, but also offers two capacity‑test modes and real‑time internal resistance readout , allowing you to evaluate battery performance from multiple angles.
Mode 1: CHARGE – Default Mode, Plug & Charge
After inserting a battery, the charger first measures the internal resistance (approx. 3 seconds) and displays it, then automatically detects battery type (3.7V Li‑ion or 1.2V Ni‑MH) and shows the voltage on screen.
Default charging current is 500mA . You can press the CURREN button within 8 seconds to select 300/500/700/1000mA (each channel can be set independently).
During charging, press the 1/2/3/4 channel keys to cycle through:
Voltage (V)
Charging current (mA)
Charged capacity (mAh)
Charging time (h)
Internal resistance (mR)
When fully charged, the display shows “End” and charging stops.
Mode 2: FAST TEST – Discharge First, Then Charge – Quick Capacity Check
Within 8 seconds of inserting a battery, press MODE to select FAST TEST , then press CURREN to choose the charging current (300/500/700/1000mA).
This mode runs two steps :
Discharge the battery first (discharge current is automatically matched: 250mA if you selected 300/500mA, or 500mA if you selected 700/1000mA);
Then charge it fully and record the charged capacity.
The final displayed capacity gives you a quick estimate of how much energy the battery can take.
Mode 3: NOR TEST – Full Charge → Discharge → Recharge – Complete Assessment
Press MODE to select NOR TEST , then set the charging current within 8 seconds.
This mode runs three steps :
Charge the battery fully ;
Automatically switch to discharge (discharge current is again matched automatically: 250mA for 300/500mA charge setting, 500mA for 700/1000mA setting) and record discharge capacity ;
Recharge fully and record the charge capacity.
After completion, the display shows “End” , and you can view the discharge capacity reference – this is the closest measurement to the battery’s actual usable energy.
💡 Note : In both test modes, the discharge current is automatically determined by your selected charging current – no manual setting needed. After the test, the charger will automatically recharge the battery to full using the same current setting, so it is ready for use.
📊 LCD Display Readings – Data for Reference Only
The large screen simultaneously shows voltage, current, time, capacity, and internal resistance – all at a glance.
The capacity (mAh) and internal resistance (mR) values are reference values calculated by the charger. They are useful for comparing the same battery over time or for rough sorting.
However, please note : due to contact resistance, ambient temperature, battery ageing, etc., these numbers are not absolutely accurate . For scientific, quality‑control, or calibration purposes, please use a professional battery analyser.
When no battery is inserted, the display shows “Null” ; if a faulty or reverse‑connected battery is inserted, it also shows “Null” (no error message, but charging will not occur).
🔋 Automatic Battery Type Recognition · Default CHARGE Mode
Upon insertion, the charger automatically detects the voltage and displays:
3.7V – Li‑ion
1.2V – Ni‑MH
CHARGE mode is the default – no further action is needed to start charging (at 500mA).
If you wish to use FAST TEST or NOR TEST , you must press MODE within the first 8 seconds after inserting the battery. Otherwise, the charger locks into CHARGE mode; you can press and hold MODE for 3 seconds to re‑enter selection.
🛡️ Multiple Safety Protections
Over‑charge, over‑discharge, short‑circuit, and temperature protection
Reverse‑polarity protection (shows “Null” and does not charge)
0V battery activation (can revive over‑discharged Li‑ion cells)
1.65V–2.2V voltage range automatically recognised as non‑rechargeable – charging is blocked
Smart –ΔV / 0ΔV cut‑off to prevent over‑charging
🔌 USB 5V Output (Special Note)
USB output is powered only by Li‑ion batteries (Ni‑MH batteries cannot supply power). Insert Li‑ion batteries into any slot(s) to get 5V/1000mA output for external devices.
One or multiple Li‑ion cells can be used in parallel; it is recommended to insert at least two cells for better stability.
Important : USB output works only when no external power adapter is connected (i.e., battery‑powered only). This is the opposite of the Lii‑500S model.
📋 Specifications
Parameter
Value
Input power
DC 12V / 2.0A ( adapter NOT included in this version – user supplied )
Li‑ion charge current
300mA / 500mA / 700mA / 1000mA (×4 channels)
Ni‑MH charge current
300mA / 500mA / 700mA / 1000mA (×4 channels)
Discharge current
Automatically matched: 250mA if charge set to 300/500mA; 500mA if set to 700/1000mA
USB output
5V / 1000mA (powered by Li‑ion batteries only, not when adapter is connected)
Compatible batteries
18650, 26650, 14500, AA, AAA, etc. (3.7V Li‑ion & 1.2V Ni‑MH)
Dimensions
162 × 96 × 36 mm
📦 Package Contents (This Version)
Lii‑500 Smart Charger × 1 unit
Bilingual (Chinese/English) User Manual × 1 copy (detailed operating instructions)
Power Adapter × 0 ( NOT included – please supply a DC 12V/2A adapter separately )
Please check the contents upon receipt; contact after‑sales support if anything is missing.
✅ Applications
Charging and capacity testing for batteries used in flashlights, power tools, instruments, digital cameras, etc.
Battery sorting, ageing assessment, and internal resistance tracking (helps identify degraded cells)
Home and travel use – four independent channels allow simultaneous charging of Li‑ion and Ni‑MH batteries
Reminder again : Capacity and internal resistance readings are for everyday reference only. For precision, use professional instruments. Always charge only batteries with the correct nominal voltage – do not charge 1.5V, 3.2V (LiFePO₄), or 3.8V (IMR) batteries. This version does NOT include an adapter – please be sure to supply your own.
LiitoKala Lii‑500 – charge, test, discharge, and measure resistance – all in one, revealing your battery’s true condition.

Tax excluded, add at checkout if applicable
Color:
Quantity
Service commitment
Shipping: ₦2,746.2
12 - 21 days
Return & Refund
7-day return window
Secure Payment
Buyer protection guaranteed
⚠️ IMPORTANT – This version (Lii-500 noother) does NOT include a power adapter
This sales package is the charger unit + manual only – the DC 12V/2A power adapter is NOT included . You must prepare a compatible adapter (DC 12V/2A output, centre‑positive, 5.5×2.1mm barrel plug) separately; otherwise the charger cannot operate.
If you prefer a bundled adapter, please choose the standard version (with adapter).
LiitoKala Lii-500 Smart Charger – Capacity Testing · Internal Resistance Measurement · 4‑Channel Independent (No Adapter Version)
⚠️ Important Notes – Read Before Use
This charger features internal resistance measurement – it will test and display the internal resistance (in mΩ) of each battery about 3 seconds after insertion, giving you a quick reference on battery health.
All displayed data (voltage, current, capacity, time, internal resistance) are for reference only and are not professional laboratory measurements. For precise battery parameters, please use dedicated testing instruments.
This charger is designed only for:
1.2V Ni‑MH batteries (AA, AAA, etc.)
3.7V cylindrical Li‑ion batteries (18650, 26650, 14500, etc.)
DO NOT charge :
1.5V primary lithium batteries (non‑rechargeable)
3.2V LiFePO₄ batteries
3.8V IMR (high‑voltage) Li‑ion batteries
Charging any of these types may cause damage or safety hazards – always check the nominal voltage on your battery!
The charger may become warm during operation – this is normal. Avoid burns. Unplug the power and remove batteries after use.
For indoor use only. A DC 12V/2A power adapter is required (this version does NOT include one – please supply your own).
🔍 Capacity Testing & Internal Resistance – Three Modes for Full Battery Assessment
The Lii‑500 not only charges batteries, but also offers two capacity‑test modes and real‑time internal resistance readout , allowing you to evaluate battery performance from multiple angles.
Mode 1: CHARGE – Default Mode, Plug & Charge
After inserting a battery, the charger first measures the internal resistance (approx. 3 seconds) and displays it, then automatically detects battery type (3.7V Li‑ion or 1.2V Ni‑MH) and shows the voltage on screen.
Default charging current is 500mA . You can press the CURREN button within 8 seconds to select 300/500/700/1000mA (each channel can be set independently).
During charging, press the 1/2/3/4 channel keys to cycle through:
Voltage (V)
Charging current (mA)
Charged capacity (mAh)
Charging time (h)
Internal resistance (mR)
When fully charged, the display shows “End” and charging stops.
Mode 2: FAST TEST – Discharge First, Then Charge – Quick Capacity Check
Within 8 seconds of inserting a battery, press MODE to select FAST TEST , then press CURREN to choose the charging current (300/500/700/1000mA).
This mode runs two steps :
Discharge the battery first (discharge current is automatically matched: 250mA if you selected 300/500mA, or 500mA if you selected 700/1000mA);
Then charge it fully and record the charged capacity.
The final displayed capacity gives you a quick estimate of how much energy the battery can take.
Mode 3: NOR TEST – Full Charge → Discharge → Recharge – Complete Assessment
Press MODE to select NOR TEST , then set the charging current within 8 seconds.
This mode runs three steps :
Charge the battery fully ;
Automatically switch to discharge (discharge current is again matched automatically: 250mA for 300/500mA charge setting, 500mA for 700/1000mA setting) and record discharge capacity ;
Recharge fully and record the charge capacity.
After completion, the display shows “End” , and you can view the discharge capacity reference – this is the closest measurement to the battery’s actual usable energy.
💡 Note : In both test modes, the discharge current is automatically determined by your selected charging current – no manual setting needed. After the test, the charger will automatically recharge the battery to full using the same current setting, so it is ready for use.
📊 LCD Display Readings – Data for Reference Only
The large screen simultaneously shows voltage, current, time, capacity, and internal resistance – all at a glance.
The capacity (mAh) and internal resistance (mR) values are reference values calculated by the charger. They are useful for comparing the same battery over time or for rough sorting.
However, please note : due to contact resistance, ambient temperature, battery ageing, etc., these numbers are not absolutely accurate . For scientific, quality‑control, or calibration purposes, please use a professional battery analyser.
When no battery is inserted, the display shows “Null” ; if a faulty or reverse‑connected battery is inserted, it also shows “Null” (no error message, but charging will not occur).
🔋 Automatic Battery Type Recognition · Default CHARGE Mode
Upon insertion, the charger automatically detects the voltage and displays:
3.7V – Li‑ion
1.2V – Ni‑MH
CHARGE mode is the default – no further action is needed to start charging (at 500mA).
If you wish to use FAST TEST or NOR TEST , you must press MODE within the first 8 seconds after inserting the battery. Otherwise, the charger locks into CHARGE mode; you can press and hold MODE for 3 seconds to re‑enter selection.
🛡️ Multiple Safety Protections
Over‑charge, over‑discharge, short‑circuit, and temperature protection
Reverse‑polarity protection (shows “Null” and does not charge)
0V battery activation (can revive over‑discharged Li‑ion cells)
1.65V–2.2V voltage range automatically recognised as non‑rechargeable – charging is blocked
Smart –ΔV / 0ΔV cut‑off to prevent over‑charging
🔌 USB 5V Output (Special Note)
USB output is powered only by Li‑ion batteries (Ni‑MH batteries cannot supply power). Insert Li‑ion batteries into any slot(s) to get 5V/1000mA output for external devices.
One or multiple Li‑ion cells can be used in parallel; it is recommended to insert at least two cells for better stability.
Important : USB output works only when no external power adapter is connected (i.e., battery‑powered only). This is the opposite of the Lii‑500S model.
📋 Specifications
Parameter
Value
Input power
DC 12V / 2.0A ( adapter NOT included in this version – user supplied )
Li‑ion charge current
300mA / 500mA / 700mA / 1000mA (×4 channels)
Ni‑MH charge current
300mA / 500mA / 700mA / 1000mA (×4 channels)
Discharge current
Automatically matched: 250mA if charge set to 300/500mA; 500mA if set to 700/1000mA
USB output
5V / 1000mA (powered by Li‑ion batteries only, not when adapter is connected)
Compatible batteries
18650, 26650, 14500, AA, AAA, etc. (3.7V Li‑ion & 1.2V Ni‑MH)
Dimensions
162 × 96 × 36 mm
📦 Package Contents (This Version)
Lii‑500 Smart Charger × 1 unit
Bilingual (Chinese/English) User Manual × 1 copy (detailed operating instructions)
Power Adapter × 0 ( NOT included – please supply a DC 12V/2A adapter separately )
Please check the contents upon receipt; contact after‑sales support if anything is missing.
✅ Applications
Charging and capacity testing for batteries used in flashlights, power tools, instruments, digital cameras, etc.
Battery sorting, ageing assessment, and internal resistance tracking (helps identify degraded cells)
Home and travel use – four independent channels allow simultaneous charging of Li‑ion and Ni‑MH batteries
Reminder again : Capacity and internal resistance readings are for everyday reference only. For precision, use professional instruments. Always charge only batteries with the correct nominal voltage – do not charge 1.5V, 3.2V (LiFePO₄), or 3.8V (IMR) batteries. This version does NOT include an adapter – please be sure to supply your own.
LiitoKala Lii‑500 – charge, test, discharge, and measure resistance – all in one, revealing your battery’s true condition.
| Category | Power & Battery Accessories |
|---|---|
| Color | Lii-500-no other |
| Brand Name | liitokala |
| Quick charge | Yes |
| Data Transmission | USB |
| High-concerned chemical | None |
| Intelligent Charge | Yes |
| Output Power | ≤37.5 |
| Origin | Mainland China |
| Display screen | Yes |
| Voltage range | No voltage |
| Power Source | Other |
| Type | Electric |
| Certification | RoHs |
| Use | Standard Battery |
| Output Current | 2A |
| Model Number | Lii-500 |
| Package | Yes |
| Output Interface | USB |
| Choice | yes |