High Quality Counter Sensor PUD-100N PUD-100NP-M8 NPN PNP Self-adhesive Label Sensor Peel Off Photoelectric Switch PUD-050NP
5.0(3 reviews)Your money is held until you receive your order, plus 7 days to report a problem. Refund if it never arrives or is not as described. Payments go through secure, licensed providers (Paystack, OPay).
18 - 28 days
Ships by express courier. Delivery times are estimates and may vary based on customs clearance.
7-day return window
Item must be unused and in original packaging.
Refund via: Original payment method
Warranty: no manufacturer warranty unless the description says so. Faulty, damaged or not-as-described items are covered by our 7-day buyer protection.
PUD-05NP is an economical and practical model. If the accuracy is not high and the speed is slow (5 times in 1 second or less), you can choose to use it. NPN PNP GENERAL MODEL (four wires)Simple setting; Four wire connection mode (wire length 2m), NPN output, Voltage DC12 ~ 24V , Wiring metho...
PUD-05NP is an economical and practical model. If the accuracy is not high and the speed is slow (5 times in 1 second or less), you can choose to use it. NPN PNP GENERAL MODEL (four wires)
Simple setting; Four wire connection mode (wire length 2m), NPN output, Voltage DC12 ~ 24V , Wiring method: Brown positive Blue negative black NPN white PNP
Widely applicable to labeling / counting and positioning of each label Label stripping industry!
PUD-100N high-precision model:
Instructions for use of photoelectric label: & nbsp; Brown connected to positive pole, blue connected to negative pole, black NPN output & nbsp; The red indicator is the status indicator and the green indicator is the output signal indicator;
1. When the product is powered on, the red indicator light is on, and the green indicator light is off or on (depending on the normally open / closed state of the product).
2. Press and hold the button for about 4 seconds, and the red light goes out. At this time, release the button, and the product enters the learning mode. The red light flashes, and the label is pulled back and forth for learning. After learning is completed, the red light stops flashing and becomes always on;
3. Press and hold the key for 4 seconds to 8 seconds, and the red indicator light goes out. If you release the key during this period, you will enter the learning mode. Press and hold the key for 8 seconds, the red indicator is normally on, and normally open / normally closed is switched, & nbsp& nbsp;& nbsp; Switch the green indicator status (from off to on, or from on to off).
4. If you press and hold the key for 8 seconds and continue to press and hold the key after the normally open / normally closed switching is completed, go back to step 2 and continue the cycle to learn and normally open / normally closed switching

Tax excluded, add at checkout if applicable
Color:
Quantity
Service commitment
Shipping: ₦2,746.2
18 - 28 days
Return & Refund
7-day return window
Secure Payment
Buyer protection guaranteed
PUD-05NP is an economical and practical model. If the accuracy is not high and the speed is slow (5 times in 1 second or less), you can choose to use it. NPN PNP GENERAL MODEL (four wires)
Simple setting; Four wire connection mode (wire length 2m), NPN output, Voltage DC12 ~ 24V , Wiring method: Brown positive Blue negative black NPN white PNP
Widely applicable to labeling / counting and positioning of each label Label stripping industry!
PUD-100N high-precision model:
Instructions for use of photoelectric label: & nbsp; Brown connected to positive pole, blue connected to negative pole, black NPN output & nbsp; The red indicator is the status indicator and the green indicator is the output signal indicator;
1. When the product is powered on, the red indicator light is on, and the green indicator light is off or on (depending on the normally open / closed state of the product).
2. Press and hold the button for about 4 seconds, and the red light goes out. At this time, release the button, and the product enters the learning mode. The red light flashes, and the label is pulled back and forth for learning. After learning is completed, the red light stops flashing and becomes always on;
3. Press and hold the key for 4 seconds to 8 seconds, and the red indicator light goes out. If you release the key during this period, you will enter the learning mode. Press and hold the key for 8 seconds, the red indicator is normally on, and normally open / normally closed is switched, & nbsp& nbsp;& nbsp; Switch the green indicator status (from off to on, or from on to off).
4. If you press and hold the key for 8 seconds and continue to press and hold the key after the normally open / normally closed switching is completed, go back to step 2 and continue the cycle to learn and normally open / normally closed switching
No questions yet. Ask about size, compatibility, delivery or anything else.
Sign in to ask a question.
| Category | Sensors & Switches |
|---|---|
| Color | PUD-050NP NPN PNP |
| Brand Name | NONE |
| High-concerned chemical | Acetochlor |
| Origin | Mainland China |
| Output | Analog Sensor |
| Theory | Optical Sensor |
| Type | Optical-Electronics Sensor |
| Use | Level Sensor |
| Material | Mixture |
| Choice | yes |
| Semi_Choice | yes |